1. How much fresh air is required?
The consultant or the applicable code sets the fresh air rate for each space. Start from that figure, not from a rule of thumb.
Good ventilation brings in fresh air, removes stale and humid air and keeps the air clean. MEPTECH supplies energy recovery ventilators, air handling units, fans, filters, air-cleaning units and sound attenuators for buildings across the UAE.
Each product has its own page with details and a quotation request.

Daikin ERV units recover heat and moisture from outgoing air to pre-condition incoming fresh air, with EC fans and a sorption energy recovery wheel.
View details →
Daikin AHUs from compact units to customised Professional ranges, with optional heat recovery.
View details →
Packaged units with fresh-air versions, extraction and free cooling for retail, showrooms and warehouses.
View details →
Inline duct, axial, centrifugal and wall or ceiling exhaust fans for extraction and supply.
View details →
Panel, pleated, bag, HEPA and carbon filters for AHUs, FCUs and ductwork.
View details →
Pollution-control units that remove odours, smoke, oil and grease particles from commercial kitchen exhaust air.
View details →
Duct silencers that cut fan and airflow noise in ventilation systems.
View details →The Daikin energy recovery ventilator range in Daikin Middle East's UAE catalogue: four sizes with a sorption energy recovery wheel and EC fans.
| 250D | 500D | 750D | 1000D | |
|---|---|---|---|---|
| Nominal supply airflow (CFM) | 250 | 500 | 750 | 1000 |
| Nominal supply airflow (l/s) | 118 | 236 | 354 | 472 |
| Nominal return airflow (CFM) | 215 | 425 | 640 | 850 |
| Nominal return airflow (l/s) | 102 | 201 | 302 | 401 |
| Supply and return fan ESP | 75 Pa | 75 Pa | 75 Pa | 75 Pa |
Source: Daikin Middle East ERV Catalogue UAE (EN). Ratings are stated at a fresh-air condition of 48 °C DB / 31.6 °C WB. Casing is 42 mm double skin with insulation; supply is 220-240 V, 1 phase, 50-60 Hz; the catalogue lists multiple filtration stages on the supply side.
Ranges listed by Daikin Middle East. Daikin states that its ventilation units include heat recovery and can recover up to 81% of outgoing heat; efficiency differs by model. Tell us the requirement and we will confirm what is available.
| Range | What it is | Stated figures |
|---|---|---|
| Heat reclaim ventilation (VAM) | Heat and moisture recovery with free cooling, standalone or with Sky Air or VRV | See Daikin catalogue |
| Modular L | Heat recovery unit with a counter-flow plate heat exchanger | ESP up to 600 Pa |
| EKVDX | Pre-conditions incoming fresh air with a separate DX coil, integrates with VRV | Fresh air 500 to 2,000 m³/h; ESP up to 150 Pa |
| Air handling units | Customisable AHUs with heat and moisture recovery | Portfolio airflows from 10 to 140,000 m³/h |
| Rooftops | Heat pump with integrated ventilation and optional heat recovery | See Daikin leaflet |
Source: Daikin Middle East ventilation page.
Six questions to settle with your consultant. Share the answers with us and we will recommend products.
The consultant or the applicable code sets the fresh air rate for each space. Start from that figure, not from a rule of thumb.
An energy recovery ventilator transfers heat and moisture between outgoing and incoming air, which reduces the load that fresh air puts on the air conditioning.
Choose the filter class for the air quality required and plan a pre-filter. See our air filters page.
Toilets, kitchens and car parks need extraction. See our fans page, and the ecology unit for commercial kitchen exhaust.
Fans and airflow create noise in ducts. Sound attenuators and cross talk attenuators control it.
Variable ventilation can follow occupancy using CO2 sensors. Tell us your control and building management requirement early.
Published by Daikin Middle East. We link to them and do not host copies.
Need a datasheet or submittal for a specific model? Ask us and we will send it.
An ERV supplies fresh air and extracts stale air, and transfers heat and moisture between the two airstreams so the incoming air arrives partly pre-cooled. It reduces the energy lost by ventilating.
Share your airflow, filtration and control requirements and we will recommend products and prepare a quotation.